2. DIP Switch and RAID Mode cross reference
User can configure any RAID mode as below by DIP switch and apply change by change mode
switch.
Dip Switch
RAID Mode
1 2 3
RAID 0(Single) ON ON ON
RAID 10 ON ON OFF
JBOD (Large) ON OFF ON
RAID 3 ON OFF OFF
Clone OFF ON ON
RAID 5 OFF ON OFF
Reserved OFF OFF ON
Normal (Single) OFF OFF OFF
Note: When DIP Switch is set to RAID 10 ----
*If you installed two HDD only, it is with RAID 1 mode
*If you installed four HDD, then, it is RAID 10 mode
2.1 RAID 0 for High Performance
RAID 0(or Stripe) is the segmentation of logically sequential data, such as a single file, so that
segments can be assigned to multiple hard disks in a round-robin fashion and thus written
concurrently. (if any one hard disk gets defective, information stored in this RAID 0 mode will be
invalid.)